EVE
Nominal Capacity: | |
---|---|
Nominal Voltage: | |
Nominal Energy: | |
Initial IR: | |
DCR: | |
Warranty: | |
Availability: | |
Quantity: | |
Nominal Voltage/Capacity | 3.2V/230Ah |
End-off-charge Voltage(Umax) | 3.65 V |
End-off-discharge Voltage(Umin) | 2.5 V (T > 0℃) 2.0 V (T ≤ 0℃) |
Standard Charging Current | 115A (0.5C) |
Maximum Instantaneous Charging Current | 2C (30 s, ≤ 80% SOC, 25℃ ± 2℃) |
Standard Discharging Current | 115A (0.5C) |
Maximum Instantaneous Discharging Current | 3C (30 s, ≥ 30% SOC, 25℃ ± 2℃) |
Charge Temperature | -10℃~65℃ |
Discharge Temperature | -35℃~65℃ |
Dimension | 53.85 mm ± 0.50 mm×173.93 mm ± 0.50 mm×207.20 mm ± 0.50 mm(With Terminal) |
Weight | 4140g±124g |
Operation Precautions
It is strictly forbidden to immerse the cell in water. When it is not in use, it should be placed in a cool and dry environment.
Do not over-charge the cell. Otherwise, cell overheating and fire may occur. During cell installation and use, hardware and software must be protected against multiple over-charge failures.
It’s necessary to set a reasonable charging time limit, otherwise, the cell may overheat, resulting in thermal runaway or fire.
It is forbidden to over-discharge. During the normal use of the cell, charge the cell regularly to keep the voltage above 2.8 V, so as to avoid over-discharge.
It is forbidden to use or place the cell at a high temperature environment. Otherwise, cell overheat, function failure or life shorten may occur.
The temperature of the cell shall not exceed 65℃ in any normal use, otherwise the BMS must shut down the cell and stop cell operation.
Please use a special charger for lithium-ion batteries when charging.
During use, please connect the positive and the negative of the cell strictly according to the labels and instructions, and reverse charging is forbidden.
It is forbidden to use metal to directly connect the positive and the negative of the cell to short-circuit. Otherwise, strong current and high temperature may cause personal injury or fire.
If the cell emits peculiar smell, heat, discoloration, deformation, or any abnormality during use, storage, or charging, immediately remove the cell from the device or charger and stop using it.